EN14605: Type 4/ Type 3 PROTECTIVE CLOTHING AGAINST LIQUID CHEMICALS

Requirements for chemical protection clothing with liquid-tight (type 3) or spray-tight (type 4) connections, including items providing only partial body protection (types PB [3] and PB [4]).


This standard sets out the minimum requirements for the following types of limited use and reuseable chemical protective clothing:


- Clothing protecting the full body with liquid-tight connections between the various clothing parts (Type 3: liquid-tight clothing) ;
- Clothing protecting the full body with spray-tight connections between the various clothing parts (Type 4: spray-tight clothing) ;
 

STANDARDS TYPE CHEMICAL PROTECTION
EN13034 6 Against splashes
EN ISO 13982-1 5 Against dust (asbestos)
EN14605 4 Against mists
EN14605 3 Against sprays

 

TESTS
General performance Tests & Specific performances Level of protection
3a 4a 5 6a
Performance
requirements
for the whole
garment
Internal pressure - - - -
Leak to interior - - X -
Penetration by a jet of liquid X - - -
Penetration by a spray (liquid spraying) - X - -
Against solid particles - - X -
Penetration by a spray (light spraying) - - - X
Performance
requirements for
seams and joints
Mechanical resistance X X X X
Resistance to permeation and penetration by liquids X X - -
Performance
requirements for the constituent materials
of the garment
Abrasion / Tearing / Perforation X X X X
Resistance to tensile strength X X - X
Resistance to cracking by bending X X X -
Resistance to cracking by bending at -30°C

X

optional

X

optional

- -
Resistance to pemeation by liquids X X - -
Resistance to penetration by
liquids
- - - X
Repulsion to liquids - - - X

a - When the protective equipment only protects certain parts of the body (torso, arms, legs), only the performance requirements for the materials making up the garment are required required (types 6, 4 and 3).

EN ISO 11611

PROTECTION USED IN WELDING AND ALLIED PROCESSES

This standard specifies the performance requirements for protective clothing for use by operators in welding and allied processes with comparable risks. This type of protective clothing is intended to protect the wearer against molten metal splash, short contact with flame and UV radiation. It is intended to be worn at ambient temperature, continuously for up to 8 hours.

 

CLASS 1 protection against low risks during welding techniques and situations producing fewer projections and low radiant heat.
CLASS 2 protection against higher risks during welding techniques and situations producing more projections and a higher radiant heat.

 

MAIVE2

EN ISO 11611

A, A2

CLASS1

 

Test Code Performances
Limited flame spread A A1 and/or A2
Molten metal splash E E1 to E3

 

EN13034 - PROTECTIVE CLOTHING AGAINST LIQUID CHEMICALS

Requirements for chemical protection clothing offering limited performance against liquid chemical products (type 6 equipment), including clothing for partial body protection (Type PB [6]).


This standard sets out the minimum requirements for limited use and reusable limited performance chemical protective clothing. Limited use chemical protective clothing is intended for use in cases of a potential exposure to light sprays, liquid aerosols or lowpressure, low-volume splashes, against which a complete liquid permeation barrier (at the molecular level) is not required.

EN1149-5

PROTECTIVE CLOTHING TO DISSIPATE STATIC ELECTRICITY

This European Standard specifies requirements for materials and the design of protective electrostatic dissipation clothing used in conjunction with a grounded system in order to prevent incendiary discharges. WARNING: These requirements may be insufficient in oxygen enriched flammable environments. This standard is not applicable for protection against mains voltages.

The control of undesirable static electricity on the person is often necessary.

The electrostatic potential may, indeed, have serious consequences on the charged individual, because it can be high enough to cause dangerous sparks.

After a risk assessment, the wearing of protective electrical dissipation clothing may be necessary. The use of clothing certified according to EN1149-5 is then adapted.

The ATEX Directive 1999/92/EC, in its Annex II-A-2.3, requests that workers be equipped with work clothes made of materials that do not produce electrostatic discharges that can ignite
explosive environments.

The electrostatic potential can also affect equipment sensitive to electric discharge. Antistatic clothing is often used on electronic manufacturing sites, assembling semiconductors for example. Finally, they are used on sites with controlled atmospheres such as automotive paint workshops, to avoid the emission of particles that may be deposited on the body paint.

The antistatic charge dissipation can be provided by a process limiting the build up of charge, or by adding carbon or metal wires. People wearing protective electrostatic charge dissipation clothing must always be grounded with a resistance of less than 10⁸Ω, for example, by wearing appropriate footwear such as the safety shoes stated in EN ISO 20345, or by other suitable means.