Ürün ve hizmet yöneticilerimizin ortak hedefi, kullanıldıkları her bölgenin yönetmeliklerine ve/veya standartlarına uygun, güvenilir, dayanıklı, yüksek performanslı ürünler sunmaktır.



This standard provides requirements for protective gloves that are worn in an environment producing ionising radiation or in an environment containing radioactive substances.
A glove protecting against radioactive contamination must be waterproof according to EN374-2.
A glove that protects against ionising radiation must, in addition to being waterproof according to EN374-2, contain a certain amount of heavy metal such as lead.
Specifications for the safety requirements for eye and face protection equipment for welding and related techniques (filters frames/ media).
Connection element or equipment component. A connector can be karabiner or a snap hook.
Class A: Anchorage connector, automatic lock used as the component and designed to be connected directly to a specific type of anchorage.
Class B: Primary connector with automatic lock used as the component.
Class M: Multi-purpose connector, primary or quick opening, used as a component, which can be loaded along its major axis or minor axis.
Class Q: Quick opening connector used in long-term or permanent applications, screw lock. When completely screwed this part is a supporting part of the
connector.
Class T: Manufactured end connector, automatic lock, designed as part of a subsystem for attachment so that the load is carried in a predetermined direction.
Component of a fall arrest equipment, which guarantees the stop of a fall from a height in safety by reducing the impact of the shock.
WARNING: If we associate a lanyard energy absorber, the total length of the entire device must not exceed 2 m.
Beschrijft de artikelen en de situaties voor individuele bescherming tegen valrisico’s.
Element of a fall arrester system to which a personal protective equipment can be fastened.
Type A - NON PPE : Anchor device with one or more stationary anchor points with the need of a structural anchor.
Type B: Anchor device with one or more stationary anchor points without the need of a structural anchor.
Type C - NON PPE : Anchor device employing a flexible anchor line with maximum deviation of 15°.
Type D - NON PPE : Anchor device employing a rigid anchor line with maximum deviation of 15°.
Type E: Anchor device for use on surfaces with a maximum slope of 5°.
Describes the equipment and test methods for PPE against falls from height.
Equipment consisting of a mobile fall arrester with self-locking, integral with its rigid anchorage line (rail, cable…). An energy reducer can be built-in on the equipment.
Equipment consisting of a mobile fall arrester with self-locking, integral with its flexible anchorage line (rope, cable…). An energy reducer (absorber) can be built-in in the equipment.
Describes the markings and information (operating instructions) on or accompanying the PPE
against falls from a height.
Standard EN ISO374-1, protective gloves against chemicals and micro-organisms, specifies the performance requirements required for gloves for protecting users against chemical products and/ or micro organisms and defines the terms to be used:
• Penetration (tested as per standard EN374-2): Diffusion of water or air, to check the impermeability, on a non-molecular level, of a chemical product and/or micro-organism through the porosities, seams, micro-holes or other imperfections present in the material of the protective glove.
• Degradation (tested as per standard EN374-4): Determination of the physical resistance of materials to degradation after continuous contact with hazardous chemicals.
• Permeation (tested as per standard EN374-3 or EN16523): Process by which a chemical product diffuses through the material of a protective glove, by continuous contact, on a molecular level. The EN ISO version of standard 374-1, introduces the concept of three types of protection against the permeation of chemicals:
- Type A: The glove gives a performance index to permeation at least equal to 2 for 6 chemical test substances taken from the list of chemicals specified in the standard.
- Type B : The glove gives a performance index to permeation at least equal to 2 for 3 chemical test substances taken from the list of chemicals specified in the standard.
- Type C : The glove gives a performance index to permeation at least equal to 1 for 1 chemical test substances taken from the list of chemicals specified in the standard.
|
LETTER CODE |
CHEMICAL PRODUCT | N°CAS |
|---|---|---|
| A | Methanol | 67-56-1 |
| B | Acetone | 67-64-1 |
| C | Acetonitrile | 75-05-8 |
| D | Dichloromethane | 75-09-2 |
| E | Carbon disulfide | 75-15-0 |
| F | Toluene | 108-88-3 |
| G | Diethylamine | 109-89-7 |
| H | Tetrahydrofurane | 109-99-9 |
| I | Ethyl acetate | 141-78-6 |
| J | n-Heptane | 142-82-5 |
| K | Caustic soda 40 % (NaOH or sodium hydroxide) | 1310-73-2 |
| L | Sulphuric acid 96 % | 7664-93-9 |
| M | Nitric acid 65% | 7697-37-2 |
| N | Acetic acid 99% | 64-19-7 |
| O | Ammonium hydroxide 25% | 1336-21-6 |
| P | Hydrogen peroxide 30% | 7722-84-1 |
| S | Hydrofluoric acid 40% | 7664-39-3 |
| T | Formaldehyde 37% | 50-00-0 |
| PASSAGE TIME MEASURED (MN) | PERFORMANCE INDEX TO PERMEATION |
|---|---|
| > 10 mn | 1 |
| > 30 mn | 2 |
| > 60 mn | 3 |
| > 120 mn | 4 |
| > 240 mn | 5 |
| > 480 mn | 6 |
The EN407 standard specifies the test methods, the general requirements, the thermal performance and the labelling of gloves and cuffs to protect from heat and fire. It applies to all gloves which must protect hands from heat and/or flames in any one or several of the following forms: fire, contact heat, convective heat, radiating heat, small spray of molten metal or large spray of melting metal.
If the product claims flammability resistance, the pictogram will be
If the product does not claim any resistance to flammability (0 or X), the pictogram will be
| PERFORMANCE LEVEL | CONTACT TEMPERATURE °C |
THRESHOLD TIME (second) |
|---|---|---|
| 1 | 100° C | ≥ 15 s |
| 2 | 250° C | ≥ 15 s |
| 3 | 350° C | ≥ 15 s |
| 4 | 500° C | ≥ 15 s |
* the performance of all test points will be limited to 2 instead of 4.