Standards and directives
The common goal of our product managers and services is to offer reliable, sustainable, high-performance products in compliance with the regulations and/or standards of each territory where they are used.

Personal protective solutions from head-to-toe
Our job is to protect women and men at work. To this effort, we design and manufacture complete personal and collective protection solutions for professionals worldwide.
System solutions
We protect men and women at work by designing and manufacturing complete collective protection solutions for professionals around the world.
Our job is to protect women and men at work. To this effort, we design and manufacture complete personal and collective protection solutions for professionals worldwide.
Delta Plus Knowledge
We help you to develop your skills through training, our tutorials and our centres of expertise. Easily find all the product and regulatory information relating to our ranges thanks to our download centre.

Training
Our mission
For more than 45 years, Delta Plus designs, standardises, manufactures, and distributes globally a full set of solutions in personal and collective protective equipment (PPE) to protect professional at work.

Our history


It contains laboratory tests to check the conformity with resistance to impacts, to cleansers and disinfectants, to temperature, to fl ame and with respiratory resistance.
Its objective is to develop test methods and requirements in the form of standards defining the technical specifications of products. Some of them, mostly requirements standards, are harmonised with EU Regulation 2016/425. Compliance with these harmonised standards gives an assurance of compliance with the requirements of EU Regulation 2016/425
Impact*: force transmitted to the headform must not exceed 5 kN at the fall of an object of 5 kg from a 1 m height. The impact energy of the helmet at
the end of the test is 49 J.
Penetration*: the tip of the mass used in the test (3 kg over 1 m) must not come into contact with the skull.
Flammability: the helmet should not burn with fl ame emission more than 5 seconds after removal of the fl ame.
* The impact and penetration tests are performed at room temperature, at 50°C and at -10°C.
In extreme temperatures: impact and penetration tests are conducted at room temperature at 150°C, at -20°C or -30°C.
Protects against accidental short-term contact with a live electrical conductor up to 440 VAC.
Protects against lateral compression. The maximum deformation of the helmet should be ≤ 40 mm.
Resistance to molten metal splashes.
Its objective is to develop test methods and requirements in the form of standards defining the technical specifications of products. Some of them, mostly requirements standards, are harmonised with EU Regulation 2016/425. Compliance with these harmonised standards gives an assurance of compliance with the requirements of EU Regulation 2016/425.