Güvenlik standartları

Birçok ülkede düzenlenen küresel bir pazarda faaliyet gösteriyoruz. Sonuç olarak, bir ülkeden veya bölgeden diğerine büyük ölçüde değişebilen gereksinimleri yönetmek zorundayız.
Ürün ve hizmet yöneticilerimizin ortak hedefi, kullanıldıkları her bölgenin yönetmeliklerine ve/veya standartlarına uygun, güvenilir, dayanıklı, yüksek performanslı ürünler sunmaktır.
#
#

Standards and certifications

All you need to know about PPE standards

Arama filtresi
Standards

EN140 : half-masks and quarter-masks

It contains laboratory tests and practical performance tests to check the conformity with resistance to impacts, to cleaners and disinfectants, to temperature, to flame and respiratory resistance.

EN148-1 : standard threaded joint

This standard is specific to the standard connection system of the cartridge for full face masks.

EN405 : half-masks fitted with valves and gas filters or compound filters

It contains laboratory tests to check the conformity with resistance to handling and wear, to impacts, to flame and with respiratory resistance.

EN143 : filters against particles

It contains laboratory tests to check the conformity with resistance to impacts, to temperature, to humidity and corrosive atmospheres and with mechanical and respiratory resistance.

EN149 : filtering half-masks

It contains laboratory tests to check the conformity with resistance to impacts, to cleansers and disinfectants, to temperature, to fl ame and with respiratory resistance.

THE REGULATION (European Union)

Its objective is to develop test methods and requirements in the form of standards defining the technical specifications of products. Some of them, mostly requirements standards, are harmonised with EU Regulation 2016/425. Compliance with these harmonised standards gives an assurance of compliance with the requirements of EU Regulation 2016/425

EN397 : Protective helmets for industry

Mandatory

Impact*: force transmitted to the headform must not exceed 5 kN at the fall of an object of 5 kg from a 1 m height. The impact energy of the helmet at
the end of the test is 49 J.
Penetration*: the tip of the mass used in the test (3 kg over 1 m) must not come into contact with the skull.
Flammability: the helmet should not burn with fl ame emission more than 5 seconds after removal of the fl ame.
* The impact and penetration tests are performed at room temperature, at 50°C and at -10°C.

Optional

In extreme temperatures: impact and penetration tests are conducted at room temperature at 150°C, at -20°C or -30°C.
Protects against accidental short-term contact with a live electrical conductor up to 440 VAC.
Protects against lateral compression. The maximum deformation of the helmet should be ≤ 40 mm.
Resistance to molten metal splashes.

Standardisation

Its objective is to develop test methods and requirements in the form of standards defining the technical specifications of products. Some of them, mostly requirements standards, are harmonised with EU Regulation 2016/425. Compliance with these harmonised standards gives an assurance of compliance with the requirements of EU Regulation 2016/425.